Broseley eVolution 7 Insert Istruzioni per gli Interventi Pagina 5

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 30
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 4
Specifications
In the UK these stoves have been approved by HETAS Ltd as intermittent heating
appliances for burning manufactured or naturally occurring smokeless fuels and wood logs
only.
eVolution 4 eVolution 7
Heat Output: 4.2 kW 7.0 kW
Weight: 100 Kg 139 Kg
Flue Gas Mass Flow: 5.22 g/s 4.1 g/s
Flue Gas Temp: 265°C 317°C
Flue Draft Required: 12-16 pa 12-16 pa
Flue Outlet Size: 6” / 150mm 6” / 150mm
Efficiency: 75.3% 80.9%
Other fulfilled Requirements
eVolution 4 Inset
BStv of the City of Munich, the City of Ragensburg and the City of Stuttgart
LRV of Switzerland
Level 1 of the BlmSchV
Sizing the appliance
It is essential that this appliance is correctly sized for the area it is required to heat. This
should be done by carrying out a heat loss calculation for the property and taking into
consideration the client’s requirements.
European standards need to be complied to when installing this appliance.
MS11-11 Issue 3 5
Vedere la pagina 4
1 2 3 4 5 6 7 8 9 10 ... 29 30

Commenti su questo manuale

Nessun commento